All of our products are available with or without retaining discs and in custom sizes. All wall ties comply with IS EN845 1-3:2013 (+A1: 2016).
New! Long wall ties for extra wide cavities. Read more
The correct type and density of wall ties is controlled by the area of unsupported brickwork, the exposure to wind, the cavity size and the nature of the structure. Detailed recommendations can be found in the following pubhlications:- IS EN845, PD6697 - Specification for metal ties for cavity wall construction B.S. 5628 Parts 1 and 2 - Use of Masonry
CPQ Chapter V - Wind Loads
| Cavity Width less than 50mm | One leaf 75mm-90mm thick. Not less than 4.9 ties /m2. |
| Cavity Width 50-75mm | Both leaves more than 90mm thick. Not less than 2.5 ties /m2. |
| Cavity width 76-100mm | Both leaves more than 90mm thick. Not less than 3 ties /m2. |
| Cavity width 101-150mm | Both leaves more than 90mm thick. Not less than 4.9 ties /m2. |
Austenitic stainless steel strip to EN10088 as required by EN845 1-3.
| 17 x 2.5mm | Test | Required |
| Tensile Strength | 15.19KN | 0.94KN |
| Compressive Strength | 2.71KN | 1.075KN |
| Anchorage Strength | 6.25KN | 2.02KN |
The tensile strength retained after being subjected to cyclic movement was in no case less than 75% of the characteristic tie tensile strength.
Based on a density of 3 ties per m2. Standards IS268 and EN845 1-3.
Cert NO. 012297 (098115) R6/06886A
![]() | S/P-(C) Flat Safety Tie |
![]() | S/C-(C) Crimped Safety Tie |
![]() | S/T-(C) Vertical Twist Safety Tie |
![]() | Channel Anchor |
![]() | RAT-(C) |
![]() | DAT-(C) Dovetail-Safety Anchors |
![]() | DAT-(C) Dovetail-Safety Anchors |
![]() | S/T/D-(C) Debonding safety tie, with durable plastic sheath |
Austenitic stainless steel strip to EN10088 as required by EN845-1-3.
| 17 x 2.5mm | Test IS268 | Required |
| Tensile Strength | 21.00KN | 0.94KN |
| Compressive Strength | 2.65KN | 1.075KN |
| Anchorage Strength | 3.39KN | 2.42KN |
The tensile strength retained after being subjected to cyclic movement was in no case less than 75% of the characteristic tie tensile strength.
Based on a density of 3 ties per m2.
Cert NO. R6/4583G
![]() | S/T-HS Vertical Twist Tie with Insulating Retaining Pin |
Features an attached Plastic Insulation Retainer.
Austenitic stainless steel strip to EN10088 as required by EN845 1-3.
| Test | Required | |
| Tensile Strength | 2.289KN | 0.94KN |
| Compressive Strength | 1.205KN | 1.075KN |
| Anchorage Strength | 2.02KN | 2.02KN |
Based on a density of 3 ties, per m2.
Cert NO. BRE 234-521
![]() | S/W- Double Triangle Wire Tie |
![]() | Double Triangle Tie S/W |
![]() | Continuous Wire Wall Tie |
![]() | S/W/- + Disc and Double Triangle Wire Tie. |
![]() | Insulation Retaining Disc |